Deadman Quick Closing Valve

The Deadman TSPRO Quick-Closing Valve provides safe and ergonomic flow control in Top Loading arms. Its fast and controlled closing reduces hydraulic impacts during operation, while the low pressure drop design preserves loading efficiency.
Up to 25% smaller than conventional valves
It interrupts the flow quickly and with less impact at high flow rates
Compatible with right and left Top Loading arms

TECHNICAL DIFFERENTIALS

Proper configuration for different orientations of the loading arm
Allows for replacement of the seals with the valve installed on the arm
Designed to operate with up to 130 m³/ha at 5 bar
Aluminum body, stainless steel components, and Viton A seals

R$ 0

Revenue lost due to repair (Conc.)

R$ 0

Revenue lost due to repair (TSPro)

R$ 0

Annual lost revenue

R$ 0

Investment difference

R$ 0

Earnings per year with TSPro
TSPRO deadman quick-closing valve, front view
Deadman TSPRO quick-closing valve, top view
Deadman TSPRO quick-closing valve, perspective view

The Deadman TSPRO Quick-Closing Valve was developed to offer greater safety and control during liquid loading operations in Top Loading systems. Its mechanism requires continuous operator action to keep the passage open. Upon releasing the actuation, the valve returns to the closed position, allowing for rapid flow interruption in operational or emergency situations. The internal geometry was designed to provide rapid closure with less impact at high flow rates, helping to minimize the effects of closing shock. Furthermore, it features up to 25% less pressure drop than conventional valves, contributing to maintaining loading efficiency and productivity. Its versatile configuration allows for installation on right or left Top Loading arms, favoring ergonomics and adapting the equipment to different loading platform layouts. Maintenance has also been simplified: seals can be replaced without removing the valve from the loading arm, reducing intervention time and equipment downtime. Manufactured with an aluminum body and piston, internal components in stainless steel, and Viton A seals, the valve offers strength, durability, and reliability for high-demand industrial operations.

Frequently asked questions

Questions about Deadman Quick Closing Valve

For what flow rate and pressure was the deadman valve designed?

For a flow rate of 130 m³/h (2,170 liters per minute) at 5 bar, with a hydrostatic test at 128 psi (9 kgf/cm²).

It is a 4" valve with standard API 1004 TTMA flanges, and the TSPRO vacuum breaker valve is available as an option.

What precautions should be taken before replacing valve seals?

Make sure the system is depressurized and free of fluid in the line before disassembling.

The seals can be replaced without removing the valve from the loading arm. The complete, step-by-step procedure is in the loading arm manual.

Technical guides

Read also

Application Top Loading Arms
Connection 4" flanged standard TTMA
Materials Aluminum and stainless steel
Seals Viton A
Design flow rate 130 m³/ha 5 bar
Hydrostatic test 128 psi — 9 kgf/cm²
Optional TSPRO vacuum breaker valve

Our engineering team provides support from the initial sizing to defining the ideal model

plugins premium WordPress